optibond solo plus instructions
- by cooper
OptiBond Solo Plus Instructions: A Comprehensive Guide
OptiBond Solo Plus is a single-component, adhesive bonding system widely utilized in modern dentistry. This guide details its proper application,
ensuring optimal adhesion for composite restorations and various dental procedures.
It’s available from suppliers like dentashop.ru and uqm-shop.ru.
OptiBond Solo Plus, manufactured by Kerr, represents a significant advancement in dental adhesive technology. It’s a single-bottle, self-etching adhesive system designed to simplify the bonding process while delivering consistently high bond strengths to enamel and dentin. This system eliminates the need for separate etching, priming, and bonding steps, streamlining the procedure for dentists and enhancing efficiency.
Widely available through dental supply retailers like dentashop.ru and uqm-shop.ru, OptiBond Solo Plus is favored for its versatility and ease of use. It’s indicated for a broad range of applications, including direct and indirect restorations, sealant application, and crown and veneer cementation. The product comes in various sizes, including 5ml bottles, catering to different clinical needs;

Its formulation incorporates a unique combination of monomers, including 4-METACRYLOXYETHYL TRIMELLITIC ANHYDRIDE (4-META), which contributes to improved adhesion and reduced microleakage. Understanding its properties and proper application techniques, as detailed in this comprehensive guide, is crucial for achieving predictable and durable restorative outcomes. The availability of different kit options, like the Universal Bottle Kit (5ml) from uqm-shop;ru, provides flexibility for dental professionals.
Composition and Properties
OptiBond Solo Plus’s effectiveness stems from its carefully balanced composition. The core of the formulation includes a proprietary blend of monomers, designed to infiltrate dentinal tubules and create a robust hybrid layer. Key components include 4-META, known for enhancing bond strength and reducing marginal leakage, alongside other methacrylate monomers that contribute to the adhesive’s overall performance.

This single-bottle adhesive contains a self-etching acidic monomer system, eliminating the need for a separate etching step. This simplifies the procedure and minimizes technique sensitivity. The solvent system facilitates wetting and penetration into the tooth structure, while the filler component contributes to improved handling characteristics and reduced polymerization shrinkage.
OptiBond Solo Plus exhibits a low film thickness, minimizing interference with the marginal fit of restorations. Its high radiopacity allows for easy differentiation from tooth structure and restorative materials on radiographs. Available in 5ml bottles (as seen on dentashop.ru), it demonstrates excellent stability and consistent performance over its shelf life when stored correctly, ensuring reliable bonding for various dental applications.
Indications for Use
OptiBond Solo Plus is a versatile adhesive system indicated for a broad spectrum of restorative procedures. Primarily, it’s used for the bonding of light-cured composite resins to tooth structure – enamel and dentin – in both direct and indirect applications. This includes Class I, II, III, IV, V restorations, and occlusal veneers.
Furthermore, it’s suitable for bonding composite resin to metal and ceramic restorations, facilitating repairs and cementation procedures. The adhesive is also indicated for the bonding of core build-ups and the sealing of dentinal hypersensitivity. Its self-etching properties make it particularly useful in minimally invasive dentistry.
OptiBond Solo Plus can be employed for the bonding of orthodontic brackets and other indirect restorative appliances. It’s a reliable choice for cementation of inlays, onlays, and crowns fabricated from various materials. As showcased by suppliers like uqm-shop.ru, its adaptability makes it a staple in modern dental practices, offering a secure and durable bond for diverse clinical scenarios.

Contraindications
While OptiBond Solo Plus is a highly effective adhesive, certain conditions warrant caution or preclude its use. The product is contraindicated in patients with known allergies to any of its components, including methacrylate resins or phosphoric acid. Avoid application in areas with active, untreated caries, as proper caries removal is essential before bonding.

Do not use OptiBond Solo Plus in situations where moisture control cannot be adequately maintained. Excessive moisture can compromise bond strength and lead to post-operative sensitivity. The adhesive is also not recommended for bonding to unpolished or poorly prepared metal surfaces, as adhesion may be suboptimal.
Furthermore, avoid using it in pulpally compromised teeth without appropriate pulp protection measures. Patients with known systemic conditions affecting wound healing should be evaluated carefully before treatment. As a general precaution, always adhere to standard dental safety protocols and manufacturer’s instructions to minimize potential adverse effects, ensuring patient safety and treatment success.
Required Materials and Equipment
Successful application of OptiBond Solo Plus necessitates a specific set of materials and equipment. Essential items include the OptiBond Solo Plus adhesive itself, available in various sizes (e.g., 5ml bottles sourced from dentashop.ru); Phosphoric acid etching gel (37% concentration) is crucial for enamel conditioning.
A microbrush applicator is needed for precise primer and bond application. Disposable mixing wells and applicators are recommended to prevent cross-contamination. A high-speed handpiece with appropriate burs is required for tooth preparation and caries removal.
A curing light, specifically one emitting wavelengths compatible with the adhesive’s photoinitiator, is indispensable for polymerization. Protective eyewear for both the operator and patient is vital. Additionally, materials for isolation – such as rubber dams, cotton rolls, and a suction device – are necessary to maintain a dry operating field. Finally, composite resin for restoration and finishing/polishing instruments complete the required inventory.
Tooth Preparation
Proper tooth preparation is foundational for successful bonding with OptiBond Solo Plus. Begin by removing all caries and existing restorative materials using a high-speed handpiece and appropriate burs. Cavity design should incorporate principles of adhesion, creating rounded internal line angles to minimize stress concentration.
Ensure adequate access and visibility for optimal bonding. The prepared tooth surface must be clean and free from debris. A thorough rinse with water and air drying are essential. Beveling enamel margins at a 45-degree angle can enhance bond strength, particularly in areas susceptible to stress.

Prior to etching, isolation is critical. Employ a rubber dam or other isolation technique to prevent salivary contamination. This step is paramount, as moisture significantly compromises bond integrity. Inspect the prepared tooth surface to confirm complete caries removal and appropriate cavity morphology, setting the stage for effective etching and bonding.
Etching Procedure with Phosphoric Acid
The etching procedure with phosphoric acid is crucial for creating the necessary micro-retentive surface for OptiBond Solo Plus adhesion. Utilize a 37% phosphoric acid gel, applying it selectively to enamel and dentin. Avoid contact with surrounding soft tissues.
Etch enamel for 15-20 seconds, resulting in a frosted appearance, indicating adequate etching. For dentin, a shorter etching time of 5-10 seconds is generally sufficient to avoid over-etching and compromising the hybrid layer. Observe for a moist, leathery appearance on dentin.
Thoroughly rinse the etched surface with a copious amount of water for at least 20 seconds to remove all traces of phosphoric acid. Ensure complete removal, as residual acid can interfere with bonding. Following rinsing, gently air-dry the tooth surface, avoiding forceful drying, which can desiccate the dentin. The etched surface should now be ready for primer application.
Primer Application
Following the etching procedure, the application of OptiBond Solo Plus primer is the next critical step. Dispense a small amount of primer onto a disposable applicator – a microbrush is ideal – and gently rub it onto the etched enamel and dentin surfaces. Ensure complete coverage, avoiding pooling in any areas.
The primer’s role is to wet the tooth surface, promoting adhesion and creating a hybrid layer. Apply the primer for approximately 15-20 seconds, allowing it to penetrate the etched surface. A uniform, shiny appearance indicates adequate wetting.
Do not light-cure the primer. It is designed to remain uncured, facilitating the subsequent bonding process. Allow the primer to dwell for a short period – approximately 5-10 seconds – to ensure proper penetration before proceeding to the bond application. Avoid any disturbance to the primed surface during this dwell time.
Bond Application
After the primer application and dwell time, proceed with the OptiBond Solo Plus bond application. Dispense a sufficient amount of bond onto a new, disposable applicator – again, a microbrush is recommended – to coat the entire prepared tooth surface. Ensure complete coverage of both enamel and dentin, mirroring the primer application technique.
Gently rub the bond onto the primed surface for approximately 5-10 seconds. This action helps to further wet the surface and optimize the adhesive interaction. Avoid excessive pressure or rubbing, which could disrupt the primed layer.
For optimal results, air-thin the bond by gently blowing air across the surface after application. This removes excess solvent and concentrates the adhesive resin. Do not light-cure the bond at this stage; it remains uncured until the composite resin is placed. Proceed immediately to composite application to prevent solvent evaporation and maintain bond integrity.
Mixing Ratio and Application Technique
OptiBond Solo Plus is a single-bottle adhesive system, eliminating the need for mixing. This simplifies the bonding procedure and reduces the risk of technique sensitivity. However, proper application is crucial for achieving optimal bond strength.
Dispense the bond onto a disposable applicator, such as a microbrush or applicator brush. Avoid using metal instruments, as they can inhibit polymerization. Apply a generous, yet controlled, amount to ensure complete coverage of the etched and primed tooth surface.
Utilize a gentle rubbing motion for approximately 5-10 seconds to thoroughly wet the enamel and dentin. This ensures the bond penetrates into the dentinal tubules, creating a robust adhesive interface. Avoid excessive manipulation or air bubbles.
Following application, air-thin the bond with a gentle stream of air to remove excess solvent and concentrate the resin. This step is vital for maximizing bond strength and minimizing polymerization shrinkage. Proceed immediately to composite placement.
Light Curing Parameters
OptiBond Solo Plus requires light curing to initiate polymerization and develop its full bonding strength. Adhering to the manufacturer’s recommended light curing parameters is essential for optimal results. Insufficient curing can lead to reduced bond strength and increased risk of microleakage.
Generally, a curing light emitting in the visible blue spectrum (wavelength of 400-500 nm) is required. The recommended curing time is typically 20 seconds with a light intensity of at least 600 mW/cm². However, always consult the specific instructions provided with your curing light unit.
Ensure the light curing tip is positioned as close as possible to the bonded surface without direct contact. This maximizes light energy delivery and ensures complete polymerization. Overlapping curing increments may be necessary for larger restorations.
Post-curing, verify the complete polymerization of the bond by checking for any tackiness or unpolymerized resin; If necessary, perform a brief post-exposure (tack-curing) to ensure a fully cured adhesive layer before proceeding with composite placement.
Composite Resin Application
Following the complete light curing of OptiBond Solo Plus, composite resin application can commence. Ensure the bonded surface remains uncontaminated during this stage to maintain optimal adhesion. Select a composite resin compatible with the adhesive system for best performance.
Apply the composite resin in incremental layers, typically 1-2mm thick. Each increment should be light-cured individually, following the composite manufacturer’s recommendations. This minimizes polymerization shrinkage stress and improves adaptation to the cavity walls.
Avoid excessive layering of composite, as it can increase the risk of technique sensitivity and potential bond failure. Utilize an instrument to condense and adapt the composite to the cavity margins, ensuring complete contact with the bonded surfaces.
Proper curing of each composite increment is crucial. Over-curing or under-curing can affect the composite’s mechanical properties and aesthetic outcome. After composite placement, perform finishing and polishing procedures to achieve a smooth, functional, and aesthetically pleasing restoration.
Post-Operative Instructions for Patients
Following a restoration utilizing OptiBond Solo Plus, patients should receive clear post-operative instructions. Initially, a slight sensitivity to temperature or pressure is common and typically subsides within a few days. Avoid extremely hot or cold foods and beverages during this period.
Maintain excellent oral hygiene, including brushing twice daily with a soft-bristled toothbrush and flossing once daily. Gentle brushing is recommended around the restored area for the first 24-48 hours.
Avoid chewing hard or sticky foods on the side of the restoration immediately after placement. This minimizes stress on the newly placed composite and allows for proper setting.
If you experience persistent sensitivity, pain, or any changes in your bite, contact your dentist promptly. Regular dental check-ups and professional cleanings are essential for maintaining the longevity of the restoration and overall oral health. Report any concerns immediately to ensure optimal results and prevent potential complications.
Potential Issues and Troubleshooting

Despite its reliability, challenges can arise when using OptiBond Solo Plus. Postoperative sensitivity is a common issue, often resolving within days, but may require desensitizing agents if prolonged.
Incomplete polymerization, indicated by a sticky or soft restoration, can occur due to insufficient light curing – ensure correct wavelength, intensity, and duration. Contamination during application, from saliva or other sources, can compromise bonding; meticulous isolation is crucial.
Microleakage, leading to secondary caries, may result from inadequate etching or improper bonding technique. If marginal discoloration appears, re-evaluation and potential replacement of the restoration may be necessary.
Bond failure can occur due to excessive occlusal forces or improper preparation. Addressing bruxism and ensuring proper occlusal adjustment are vital. Always follow the manufacturer’s instructions precisely to minimize these potential issues and achieve optimal bonding success.
Sensitivity Management

Postoperative sensitivity is a frequent concern following restorative procedures utilizing OptiBond Solo Plus. This typically stems from dentinal tubule exposure during preparation or the bonding process. Initial management involves patient education, emphasizing the usually transient nature of the discomfort.
Mild sensitivity often resolves spontaneously within 24-72 hours. However, for persistent symptoms, several strategies can be employed. Fluoride varnish application is a conservative approach, aiding in tubule occlusion and reducing sensitivity.
Desensitizing agents containing potassium nitrate or strontium chloride can be applied topically or incorporated into a home-use toothpaste. Avoiding thermal extremes and acidic foods can also minimize discomfort.
In severe cases, a calcium hydroxide liner may be considered before restoration. If sensitivity persists despite these measures, a thorough re-evaluation of the restoration and potential alternative bonding protocols may be necessary. Proper technique minimizes the risk, but proactive management is key.
Shelf Life and Storage Conditions
Maintaining the integrity of OptiBond Solo Plus is crucial for optimal performance. The unopened shelf life, as specified by Kerr, is typically two years from the date of manufacture, provided proper storage conditions are adhered to.
Once opened, the product should be used within six months to ensure consistent bonding efficacy. Exposure to air and moisture can degrade the adhesive properties over time.
Optimal storage requires keeping the bottle tightly sealed when not in use, and storing it in a cool, dry place, away from direct sunlight and heat sources. Refrigeration is generally not recommended, as temperature fluctuations can compromise the material.
Avoid contamination of the nozzle with saliva or other materials, as this can introduce bacteria and affect the adhesive’s performance. Regularly inspect the product for any signs of discoloration or precipitation, which may indicate degradation. Discard any compromised material immediately.
Clinical Studies and Research
OptiBond Solo Plus has been the subject of numerous clinical studies and research investigations, demonstrating its consistent performance and reliability as a dental adhesive system. These studies have focused on evaluating its bond strength to various dental substrates, including enamel and dentin, under different clinical conditions.
Research consistently highlights its ability to provide durable adhesion, minimizing microleakage and secondary caries. Investigations have also explored its compatibility with different composite resins and its effectiveness in various restorative procedures, such as direct restorations, indirect restorations, and orthodontic bonding.
Studies have shown that OptiBond Solo Plus exhibits a high degree of hydrolytic stability, meaning it maintains its bond strength over time in a moist oral environment. Furthermore, research supports its low sensitivity and minimal postoperative discomfort for patients.
Ongoing research continues to refine application techniques and explore new applications for this versatile adhesive, solidifying its position as a trusted choice among dental professionals.
Comparison with Other Bonding Agents
OptiBond Solo Plus distinguishes itself from other bonding agents through its simplified, single-bottle application, reducing technique sensitivity. Unlike multi-step systems, it eliminates the need for separate etching, priming, and bonding steps, streamlining the restorative process.
Compared to some universal adhesives, OptiBond Solo Plus often demonstrates superior bond strength to enamel, particularly in challenging conditions. While universal adhesives offer versatility across substrates, OptiBond Solo Plus excels in specific applications where enamel bonding is critical.
Some bonding agents require extensive drying protocols, whereas OptiBond Solo Plus exhibits good performance with slightly moist dentin, potentially reducing the risk of sensitivity. However, certain self-etch adhesives may offer faster application times.
Ultimately, the choice of bonding agent depends on the clinical situation and the dentist’s preference. OptiBond Solo Plus provides a balance of reliability, ease of use, and consistent performance, making it a strong contender in the market.
Advantages of OptiBond Solo Plus
OptiBond Solo Plus offers several key advantages for dental professionals. Its single-bottle system significantly simplifies the bonding procedure, reducing chair-side time and minimizing technique sensitivity. This streamlined approach contributes to greater consistency in results.
The adhesive demonstrates excellent bond strength to both enamel and dentin, ensuring durable and long-lasting restorations. It exhibits reliable performance in various clinical scenarios, including direct restorations, indirect cementation, and orthodontic bonding.
OptiBond Solo Plus’s ability to bond to moist dentin can reduce post-operative sensitivity, a common concern with other bonding agents. This feature is particularly beneficial in deep cavities or when treating patients with sensitive teeth.
Furthermore, its low film thickness minimizes the risk of marginal discoloration and promotes accurate adaptation of composite resins. The product’s consistent quality, as offered by suppliers like dentashop.ru and uqm-shop.ru, adds to its reliability and predictability.
Disadvantages of OptiBond Solo Plus
Despite its numerous benefits, OptiBond Solo Plus does present some potential drawbacks. Some clinicians report a relatively short working time after acid etching, requiring efficient application to maintain optimal bonding. This can be challenging in complex cases or with less experienced operators.
The adhesive’s solvent-based composition can lead to slight enamel etching, potentially affecting the marginal integrity of restorations over extended periods. While generally minimal, this is a consideration for long-term clinical success.
Compared to some newer, self-etching adhesives, OptiBond Solo Plus requires a separate etching step, adding an extra procedural stage. This can increase the overall treatment time and complexity.
Certain patients may experience post-operative sensitivity, although this is generally less frequent than with some alternative bonding systems. Proper technique and careful application are crucial to minimize this risk. Availability through suppliers like dentashop.ru and uqm-shop.ru doesn’t negate these potential issues, highlighting the need for informed clinical judgment.
Safety Precautions
When utilizing OptiBond Solo Plus, strict adherence to safety protocols is paramount. This dental adhesive contains chemicals that require careful handling to protect both the practitioner and the patient.
Personal Protective Equipment (PPE) is essential. Always wear gloves, safety glasses, and a protective mask to prevent skin and eye contact, as well as inhalation of vapors. Ensure adequate ventilation in the treatment area.
In case of skin contact, immediately wash the affected area with copious amounts of soap and water. For eye contact, flush thoroughly with water for at least 15 minutes and seek medical attention.
OptiBond Solo Plus is for dental use only and should not be ingested. Keep the material out of reach of children. Proper disposal of used materials, following local regulations, is crucial.
Review the Material Safety Data Sheet (MSDS) before use for comprehensive safety information. Suppliers like dentashop.ru and uqm-shop.ru should provide access to this documentation. Always prioritize a safe working environment when employing this bonding agent.
Frequently Asked Questions (FAQ)
Q: Can OptiBond Solo Plus be used with all composite resins?
A: Yes, it demonstrates excellent compatibility with a wide range of light-cured composite resins commonly available, including those sourced from suppliers like dentashop.ru and uqm-shop.ru.
Q: Is etching required before using OptiBond Solo Plus?
A: Generally, yes. Phosphoric acid etching is typically recommended to create the necessary micro-retentive surface for optimal bonding, though self-etching techniques can be considered based on the clinical situation.
Q: What is the typical shelf life of OptiBond Solo Plus?
A: Unopened bottles generally have a shelf life of two years from the date of manufacture. Always check the expiration date printed on the packaging.

Q: Can I rebond with OptiBond Solo Plus if the initial bond fails?
A: Rebonding is possible, but requires complete removal of the old adhesive and a fresh etching and bonding procedure.
Q: Where can I purchase OptiBond Solo Plus?
A: It’s readily available through dental supply companies such as dentashop.ru and uqm-shop.ru, as well as other authorized dental distributors.
OptiBond Solo Plus stands as a reliable and versatile bonding agent within contemporary restorative dentistry. Its single-bottle application simplifies procedures, while consistently delivering strong and durable adhesion to tooth structure and restorative materials. Proper implementation, adhering to the detailed instructions outlined – from etching and priming to light curing – is paramount for achieving predictable clinical outcomes.
Availability through reputable suppliers like dentashop.ru and uqm-shop.ru ensures access to genuine product. While generally user-friendly, understanding potential issues, such as sensitivity or bond failure, and employing appropriate troubleshooting techniques are crucial.
Ultimately, OptiBond Solo Plus, when used correctly, contributes significantly to the longevity and success of composite restorations. Continued research and clinical studies further validate its efficacy, solidifying its position as a trusted choice for dental professionals seeking a high-performance bonding solution.
Related posts:
Need help with OptiBond Solo Plus? Find clear, easy-to-follow instructions & manuals instantly at ManualCenterPDF! Get bonding right, first time.
Posted in Instructions